Search results for " DC microgrid"
showing 3 items of 3 documents
Modeling and Experimental Validation of a Voltage-Controlled Split-Pi Converter Interfacing a High-Voltage ESS with a DC Microgrid
2023
The Split-pi converter can suitably interface an energy storage system (ESS) with a DC microgrid when galvanic isolation is not needed. Usually, the ESS voltage is lower than the grid-side voltage. However, limitations in terms of the ESS current make the use of a high-voltage ESS unavoidable when high power levels are required. In such cases, the ESS voltage can be higher than the microgrid voltage, especially with low microgrid voltages such as 48 V. Despite its bidirectionality and symmetry, the Split-pi exhibits a completely different dynamic behavior if its input and output ports are exchanged. Thus, the present work aims to model the Split-pi converter operating with an ESS voltage hi…
Modeling and Performance Assessment of the Split-Pi Used as a Storage Converter in All the Possible DC Microgrid Scenarios. Part I: Theoretical Analy…
2021
The integration of an electrical storage system (ESS) into a DC microgrid using a bidirectional DC/DC converter provides substantial benefits but requires careful design. Among such converter topologies, the Split-pi converter presents several merits at the cost of non-isolated operation. However, the few works in the literature on the Split-pi presented only closed-loop control with a single control loop; furthermore, they neglected the reactive components’ parasitic resistances and did not perform any experimental validation. This work aimed at investigating the use of the Split-pi converter as a power interface between an ESS and a DC microgrid. Five typical microgrid scenarios are prese…
Modeling and Performance Assessment of the Split-Pi Used as a Storage Converter in All the Possible DC Microgrid Scenarios. Part II: Simulation and E…
2021
Bidirectional DC/DC converters such as the Split-pi can be used to integrate an energy storage system (ESS) into a DC microgrid providing manifold benefits. However, this integration deserves careful design because the ESS converter must behave like a stiff voltage generator, a non-stiff voltage generator, or a current generator depending on the microgrid configuration. Part I of this work presented a comprehensive theoretical analysis of the Split-pi used as an ESS converter in all the possible DC microgrid scenarios. Five typical microgrid scenarios were identified. Each of them required a specific state-space model of the Split-pi and a suitable control scheme. The present paper complete…